← Back to PureOneIllustrative sample · fabricated property & data
Mold Inspection Report
PO-8841 · v3
Finalized · locked
Property
Single-family residence — Portland, OR 972██
Client
R. Okafor (sample)
Property type
Residential
Inspected
2026-06-11
Inspector
Marcus Reyes, CMI (Certified Mold Inspector)
License
OR-MA-4471
Interpreted by s520-engine@1.0.0 · pureone-thresholds-v1 · content hash a3f9c1d4e7b2…e1

Overall determination

Condition 3Severe riskEngine draft — required human confirmation
  • Judgment⚑ needs human
    COND-PENDING-SAMPLE

    Condition pending source confirmation — sampling suggests possible indoor source (Master bedroom); attester must confirm a Condition 3 area before Condition 2/3 is asserted.

Human attestation

The engine flagged this determination as requiring a certified human to confirm — it does not self-certify a mold condition. Confirmed and attested by Marcus Reyes, CMI (Certified Mold Inspector), License #OR-MA-4471 on 2026-06-12 09:15.

I have reviewed the AI-assisted analysis and field evidence and attest, in my professional judgment as the named certified inspector, to the Condition classification stated in this report.

Air sample results — indoor vs. outdoor baseline

GenusIndoorOutdoor
Cladosporium4301180
Basidiospores210870
Aspergillus / Penicillium510340
Stachybotrys· indoor-only1400
Total (spores/m³)12902390
Master bedroomSevere riskindoor-only: stachybotrysindoor/outdoor = 0.54×
  • S520 · interpreted
    AIR-NO-THRESHOLD

    No established numeric spore-count threshold is published; counts inform professional judgment, they do not pass/fail an environment; pending edition verification.

  • Convention
    AIR-TIERA-PRESENT

    Indoor chronic-water genera (Stachybotrys/Memnoniella/Chaetomium) — conventionally flagged highest; these under-aerosolize so any meaningful indoor detection is significant.

  • Convention
    AIR-WATERGENERA-LOW

    Water-indicator genera present indoors but absent outdoors: stachybotrys. Conventional indoor-source indicator.

Recommended remediation scope

  • containment
    Establish containment / engineering controls
    S520 · interpreted

    Contamination control — containment to prevent cross-contamination; pending edition verification.

  • other
    Correct the moisture source
    S520 · interpreted

    Moisture-source correction required for durable remediation (mold is a moisture problem); pending edition verification.

  • removal
    Physical removal of contaminated materials + HEPA cleaning
    S520 · interpreted

    Physical removal is the primary method. NOTE: the standard's stance on whether biocides are REQUIRED has nuance across editions — this is NOT asserted as "S520 does not require biocide" until the current-edition wording is pinned.

  • drying
    Dry to normal moisture content
    S520 · interpreted

    Drying to normal moisture content before closeout; pending edition verification.

  • treatment
    Antimicrobial / biocide treatmentoptional — not defaulted
    Convention

    Antimicrobial/biocide line included at firm discretion — optional. Whether S520 requires/discourages biocide is not asserted here (unverified across editions).

  • testing
    Post-remediation verification (clearance)
    S520 · interpreted

    Verification = no visible growth + dried to normal moisture content + professional judgment that Condition 1 is restored; pending edition verification.

Provenance ledger — 17 interpretive decisions, every one tagged

S520 · interpreted×9Convention×5Judgment×1Guardrail×2

Nothing is asserted as bare S520 — every standard-derived call is tagged S520-INTERPRETED (pending edition verification), conventions are labelled as conventions, and judgment calls are flagged for a human. That separation is the auditable record an insurer or attorney can follow line by line.

Disclaimers

  • S520 · interpreted
    DISC-DATE

    Findings reflect conditions observed on the inspection date only.

  • Guardrail
    DISC-NONDIAG

    Non-diagnostic — this report does not diagnose, treat, or assert health causation (clinician-only domain).

  • Guardrail
    DISC-ASSIST

    Product assists; the named certified human attests to the Condition classification.

Everything above was produced by PureOne's S520 interpretive engine from the sample data — including the provenance and the human-confirmation flag. Real reports draw lab results from independent accredited laboratories.